Blocklayer.com Construction Calculators Online
Bookmark Bookmark! Tell a Friend Tell A Friend!
 
Total Rise

Ideal Rise
Show Nosing
Show Stringer
Restrict








(Keep Total Run)


Possible Rises
Stringer Width
Concrete Thickness
  Stair Width
Total Rise must be greater than Headroom Show Headroom
  Headroom
  Floor Thickness


Stair Calculator. Rise Run Headroom layout

Total Rise 2000
10 Runs of 250
11 Rises of 181.8




Stringer Calculator. Dimensions layout
Stringer Run (! top of treads) -> 309, 618, 927, 1236, 1546, 1855, 2164, 2473, 2782, 3091, 3400

Concrete Volume 0.8 m³

The stairs have a total run of 2500mm and total rise of 2000mm, with 11 rises of 181.8mm. The angle is 36°, the Stringer is 3400 long and 297 wide. With a thickness of 150mm, and stair width of 1200mm, the concrete volume is 0.8m³. The void volume (under the stairs) is 2.2m³. The Base of the stairs (for formwork) has a total run of 2245mm, and rise of 1633mm. The base length (on the angle) is 2776mm


Print Your Own Event & Theatre Admission Tickets + Raffle Tickets

Design tickets Free Online and print to your printer!




If you've benefitted form this free service, please consider a small donation to Operation Eyesight

Scan QR Code with your Mobile Phone Home Blocklayer.com

Wonga Beach Q.L.D. Australia
Operation Eyesight - Donate a Dunny
Donate a Dunny


Questions or Suggestions? Email Email or ph: +61 7 40987645

Blocklayer.com Builders Calculators Online - Stair Layout Calculator
Got an idea ideas for a new calculator or a way to improve this one? Please let us know!



ALWAYS CHECK WITH YOUR LOCAL BUILDING AUTHORITY BEFORE LAYING OUT
OR BUILDING STAIRS, AND FOLLOW ALL LOCAL CODES


Disclaimer | Privacy